RWD Life Science

Veterinary multi-parameter monitor

Code RM300/RM400S/RM400M
The RWD veterinary monitors are intended for veterinary hospitals or clinics and other special procedures laboratories. Monitorable parameters include SpO₂, ECG, NIBP, TEMP, RESP, ETCO₂.
Lasīt vairāk par produktu
funkcijos
  • 10.4″Color TFT-LCD screen, intuitive and easy to operate.
  • Can store the trend data for 120 – 168 hours and has the function of displaying trend data
    and trend graphs.
  • Function of alarm event reviewing, can store 1000 – 1800 pieces of alarm events.
  • Anti-perfusion digital blood oxygen saturation measurement, sensitive and reliable.
  • Multiple measuring functions include 5-lead ECG/HR, RESP, TEMP, SpO2
    /Pulse, NIBP.
  • The complete builtin module design ensures stable performance, easy replacement and
    maintenance.
  • Multiple display methods to meet individual needs.
  • Equipped with 5 cuffs of different sizes to meet the measurement needs of various body
    types
  • Unique all-lead ECG on-one-screen display, which can facilitate the diagnosis and analysis
    of cardiac disease.
  • High-Frequency Electro tome Resistant & Defibrillation Effects Resistant.
  • With 270° degrees view alarm light design and 3 levels of alarm, it is clearer
Specifikacija

Size and weight

  • Size: 318 mm×264 mm×152 mm
  • Weight: 4.5 kg

Power supply

  • Power voltage: AC 100-240V
  • Frequency: 50/60Hz
  • Input current: 0.6A -0.3A
  • Fuse: T 2A/250V, integrated in the power module
  • Earth leakage current: <0.3 mA
  • Safety class: Category I

Display

  • Size: 12.1″
  • Type: Color TFT-LCD
  • Resolution: 800×600 pixels or higher

Indicators

  • Physiological alarm LED: 1(Yellow/Red)
  • Technical alarm LED: 1(Blue)
  • AC Power LED: 1 (Green/Orange)
    Battery Charge LED: 1 (Yellow)

Interface

  • Power: 1 AC power inlet
  • Wired network: 1, standard RJ45 socket
  • Equipotential grounding terminal: 1

Battery

  • Type: Rechargeable lithiumion battery
  • Type: 11.1V/4.0AH
  • Charge time: ≤6 hours (2 batteries for 12 hours)
  • Operating time under the normal use and full charge: ≥240 minutes(2 batteries for 480 minutes)
  • Operating time under the normal use and full charge: New and fully charged battery at 25℃ ambient temperature and NIBP work on AUTO mode for 20 minutes interval.
  • Operating time after the first alarm if low battery: ≥10 minutes

BLT-SpO2

  • Measurement range: 0~100%
  • Resolution: 0,01
  • Accuracy: At 70~100%, ±2%
  • Accuracy: At 0~69%, unspecified
  • Data update period: <13 s
  • Alarm: User-selectable upper and lower SpO2 limits
  • Measurement range: 25~250 bpm
  • Resolution: 1 bpm
  • Accuracy: ±1% or ±1 bpm, whichever is greater
  • Data update period: <13 s
  • Alarm: User-selectable upper and lower pulse rate limits

EtCO2 (sidestream, BLT)

  • Measure method: Infrared spectrum
  • Measure mode: Sidestream
  • Measurement Range: 0.0~13.1% (0~99.6 mmHg)
  • Resolution: 1 mmHg
  • Unit: %, mmHg, kPa
  • Accuracy: At <5 % CO2,±0.3% (±2.0 mmHg)Accuracy: At ≥5 % CO2, < ±10 % of reading
  • Range of respiration rate measurement: 3~150 rpm
  • Calibration: Offset calibration: auto, manual or gain calibration
  • Range of alarm: 0.0~13.1 % (0~99.6 mmHg), continuously adjustable between upper limit and lower limit
  • Alarm indication: Sound and light indication

EtCO2 (mainstream CAPNOSTAT5)

  • Measure method: Infrared spectrum
  • Measure mode: Mainstream
  • Warm up time: Capnogram displayed in less than 15 s. At an ambient temperature of 25 ℃ , full specifications
  • Warm up time: within 2 minutes.
  • CO2 measurement range: 0 ~ 19.7%(0 ~ 150 mmHg)
  • CO2 resolution: 1 mmHg
  • CO2 accuracy:
    - 0 ~ 40 mmHg, ±2 mmHg
    - 41 ~ 70 mmHg, ±5% of reading
    - 71 ~100 mmHg, ±8% of reading
    - 101 ~ 150 mmHg, ±10% of reading temperature at 35℃.
  • CO2 Stability: Short-term Drift: Drift over four hours≤0.8 mmHg. Long-term Drift: Accuracy specification will be maintained over a 120 hours period.
  • Rise time: <60ms
  • Unit: %, mmHg, kPa
  • Respiration rate range: 0~150 rpm
  • Respiration rate accuracy: ±1 rpm
  • Alarm indication: Sound and light indication

Recorder (optional)

  • Type: Thermal dot array
  • Paper width: 50 mm
  • Recording waveform: single track, 3 tracks
  • Recording speed: 12.5 mm/s, 25 mm/s, 50 mm/s
Modeliai
Nosaukums
RM300  Veterinary monitor with SpO₂, ECG, RESP, NIBP,TEMP and HR
RM400M  Veterinary monitor with SpO₂,ECG, RESP, HR, NIBP, TEMP, and EtCO₂ (Mainstream)
RM400S  Veterinary monitor with SpO₂, ECG, RESP, HR, NIBP, TEMP and EtCO₂(Sidestream)