Oxygen sensors for OxyLite
A wide selection of oxygen sensors is available to suit both physiological (in vivo) monitoring and a variety of in vitro applications. Sensors featuring integrated thermocouples support automatic temperature-compensation of oxygen readings. Oxygen sensors are supplied in sealed Tyvek® pouches.
Bare-fibre oxygen sensors
- NX-BF/O/E Oxygen-only bare-fibre sensor
Flexible, minimally invasive sensor suitable for localized oxygen measurements from virtually any tissue type, or for in vitro dissolved oxygen applications.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time approx. 20 s
Manual temperature compensation required
Removable/adjustable Luer
MRI compatible
Dimensions:
Tip diameter: approx. 250 µm
Exposed tip fibre length: 6 cm
Total sensor length: 2.5 m
Reusability: Limited due to fragility
NOTE: THIS SENSOR TYPE IS ALSO AVAILABLE IN 8 M LENGTH FOR MRI APPLICATIONS
- NX-BF/OT/E Oxygen/Temperature bare-fibre sensor
Flexible, minimally invasive sensor suitable for localized combined oxygen/temperature measurements from virtually any tissue type, or for in vitro dissolved oxygen applications.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time approx. 20 s
Automatic temperature compensation
Removable/adjustable Luer
Dimensions:
Tip diameter: approx. 350 µm
Exposed tip fibre length: 6 cm
Total sensor length: 2.5 m
Reusability: Limited due to fragility
Needle oxygen sensors
- NX-NP/O/E Oxygen-only needle-encased sensor
23G surgical steel-encased sensor featuring greater physical robustness, suitable for localized oxygen measurements from virtually any tissue type, or for in vitro dissolved oxygen applications. Oxygen detection via lateral 'windows' distal from the sensor tip. Larger tissue sampling area/volume than bare-fibre type sensors (1 mm?).
Tissue placement: directly, or via introducer (e.g. Angiocath®)
T-90 response time approx. 3 min
Manual temperature compensation required
Fixed/potted Luer
Dimensions:
Needle diameter: approx. 650 µm
Exposed needle length: 6 cm
Total sensor length: 2.5 m
Reusability: Good
Large area oxygen sensors
- NX-LAS-1/O/E Oxygen-only large area sensor (1 mm?)
Sensor tip shielded within a short 23G surgical steel cage, oxygen detection via lateral 'windows', 1 mm? tissue sampling area/volume. Suitable for localized oxygen measurements from virtually any tissue type, or for in vitro dissolved oxygen applications.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time – approx. 3 min
Manual temperature compensation required
Dimensions:
Tip cage diameter: 630 µm
Tip cage length: 5 mm
Sleeving diameter: 820 µm (first 50 cm)
Total sensor length: 2.5 m
Reusability: Good
- NX-LAS-8/O/E Oxygen-only large area sensor (8 mm?)
Sensor tip shielded within an extended 23G surgical steel cage, oxygen detection via lateral 'windows', very large tissue sampling area/volume (8 mm?) for area-averaged tissue oxygen measurements.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time – approx. 3 min
Manual temperature compensation required
Dimensions:
Tip cage diameter: 630 µm
Tip cage length: 12 mm
Sleeving diameter: 820 µm (first 50 cm)
Total sensor length: 2.5 m
Reusability: Good
- NX-LAS-8/OT/E Oxygen/Temperature large area sensor (8 mm?)
Combined oxygen/temperature sensor tip shielded within an extended 23G surgical steel cage, oxygen detection via lateral 'windows', very large tissue sampling area/volume (8 mm?) for area-averaged tissue oxygen/temperature measurements.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time – approx. 3 min
Automatic temperature compensation
Dimensions:
Tip cage diameter: 630 µm
Tip cage length: 12 mm
Sleeving diameter: 820 µm (first 50 cm)
Total sensor length: 2.5 m
Reusability: Good
Implantable oxygen sensors
- NX-CI/BF/O/E Implantable bare-fibre type oxygen sensor
Flexible, minimally invasive oxygen sensor suitable for chronic tissue implantation.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time approx. 20 s
Manual temperature compensation required
NX-CI ADAPTER required (see accessories)
Supplied with calibration on iButton device
MRI compatible
Dimensions:
Tip diameter: approx. 250 µm
Exposed tip fibre length: 60 mm (default); 2 mm minimum
Ferrule length: 10 mm
Reusability: Intended for single use
- NX-CI/LAS-1/O/E Implantable large area type oxygen sensor (1 mm?)
Sensor tip shielded within a short 23G surgical steel cage, oxygen detection via lateral 'windows', 1 mm? tissue sampling area/volume.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time – approx. 3 min
Manual temperature compensation required
Dimensions:
Tip cage diameter: 630 µm
Tip cage length: 5 mm
Sleeving diameter: 820 µm
Length from ferrule: 60 mm
Ferrule length: 10 mm
Reusability: Intended for single use
- NX-CI/LAS-8/O/E Implantable large area type oxygen sensor (8 mm?)
Sensor tip shielded within an extended 23G surgical steel 'cage', oxygen detection via lateral 'windows', very large tissue sampling area/volume (8 mm?) for area-averaged tissue oxygen measurements.
Tissue placement via introducer (e.g. Angiocath®)
T-90 response time – approx. 3 min
Manual temperature compensation required
Dimensions:
Tip cage diameter: 630 µm
Tip cage length: 12 mm
Sleeving diameter: 820 µm
Length from ferrule: 60 mm
Ferrule length: 10 mm
Reusability: Intended for single use
- OxyLite
- NX-CI ADAPTER for implantable ('CI' type) oxygen sensors
Nosaukums | |
---|---|
NX-BF/O/E Oxygen-only bare-fibre sensor | |
NX-BF/OT/E Oxygen/Temperature bare-fibre sensor | |
NX-NP/O/E Oxygen-only needle-encased sensor | |
NX-LAS-1/O/E Oxygen-only large area sensor (1 mm2) | |
NX-LAS-8/O/E Oxygen-only large area sensor (8 mm) | |
NX-LAS-8/OT/E Oxygen/Temperature large area sensor (8 mm2) | |
NX-CI/BF/O/E Implantable bare-fibre type oxygen sensor | |
NX-CI/LAS-1/O/E Implantable large area type oxygen sensor (1 mm2) | |
NX-CI/LAS-8/O/E Implantable large area type oxygen sensor (8 mm2) |