Blood flow probes for OxyFlo
Surface blood flow probes
- Standard probe for blood flow from tissue surfaces, cat. no. MSP100NX
These robust and easy-to-handle probes are ideal for measurements of microvascular blood flow on tissue surfaces.
Tissue attachment via double-sided adhesive rings (product code 'MSP140AR').
Dimensions:
Head diameter: 17 mm
Head height : 8 mm
Total probe length: 3 m
Reusability: Unlimited
- Digit probe for blood flow from rounded surfaces, cat. no. MSP110NX
Specifically developed with a curved geometry for measuring cutaneous blood flow in the digits.
Tissue attachment via double-sided adhesive rings (product code MSP140AR).
Dimensions:
Head diameter: 17 mm
Head height : 10 mm
Total probe length: 3 m
Reusability: Unlimited
- Miniature probe for blood flow from tissue surfaces (suturable), cat. no. MSP300NX
Small and lightweight, suitable for non-invasive tissue surface blood flow monitoring and for semi-invasive monitoring of blood flow from muscle and internal organ surfaces.
Tissue attachment via double-sided adhesive rings (product code 'MSP140AR') or by suture.
Dimensions:
Head diameter: 12 mm
Head height : 5 mm
Total probe length: 3 m
Reusability: Unlimited
- Miniature probe for blood flow from tissue surfaces (non-suturable), cat. no. MSP310NX
Small and lightweight, suitable for non-invasive tissue surface blood flow monitoring and for semi-invasive monitoring of blood flow from muscle and internal organ surfaces.
Tissue attachment via double-sided adhesive rings (product code MSP140AR).
Dimensions:
Head diameter: 12 mm
Head height : 5 mm
Total probe length: 3 m
Reusability: Unlimited
Needle blood flow probes
- Standard needle blood flow probe, cat. no. MNP100NX
Standard, robust needle probe for invasive blood flow measurements or non-invasive blood flow measurements from tissue surfaces.
Typically positioned using an external clamp.
Dimensions:
Needle length: 30 mm
Needle diameter : 1 mm
Collar length: 16 mm
Collar diameter: 5 mm
Total probe length: 3 m
Reusability: Unlimited
- Standard needle blood flow probe for MCAO, cat. no. MNP100NX-3/10
Specifically conceived for cerebral microvascular blood flow measurements in MCAO and stroke applications.
Typically positioned using an external clamp or using dedicated miniature holders (product codes MH-10 and MH-05).
Dimensions:
Needle length: 10 mm
Needle diameter : 1 mm
Collar length: 16 mm
Collar diameter: 5 mm
Total probe length: 3 m
Reusability: Unlimited
- Fine needle blood flow probe, cat. no. MNP110NX
This micro-needle probe has been developed for minimal tissue trauma during invasive insertion and is frequently used for measuring microvascular blood flow within muscle, tumours, internal organs and brain tissue.
Typically positioned using an external clamp.
Dimensions:
Needle length: 30 mm
Needle diameter : 0.5 mm
Collar length: 16 mm
Collar diameter: 5 mm
Total probe length: 3 m
Reusability: Unlimited
- Bent-tip needle blood flow probe, cat. no. MNP150NX
An angled probe tip facilitates blood flow measurements in specialist applications such as gingiva and nasal mucosa.
Typically positioned using an external clamp.
Dimensions:
Needle length: 30 mm
Needle diameter : 1 mm
Collar length: 16 mm
Collar diameter: 5 mm
Total probe length: 3 m
Reusability: Unlimited
Specialist blood flow probes
- Single-fibre implantable blood flow probe, cat. no. MSF100NX
This highly flexible probe consists of a 0.5mm diameter polymethyl methacrylate (plastic) fibre with a standard length of 30cm. Particularly useful for chronic implantation, the MSF100NX can be directly inserted into tissue using a standard 22G i.d. cannula. The small and light coupling bead minimizes the total weight of the implanted probe. Flow measurements are made by attaching the MSF Driver (product code MSFD NX).
Dimensions:
Fibre length: 30 cm
Fibre diameter: 0.5 mm
Collar length: 8 mm
Collar diameter: 3 mm
Reusability: Disposable
- Bare-fibre type blood flow probe, cat. no. NX-BF/F
This blood flow probe consists of a pair of 125 µm glass fibres for a combined diameter of less than 300 µm and a tip length of 60 mm. This probe type represents a minimally invasive and flexible alternative to the steel needle probes above and is particularly useful for direct insertion into tissue (via catheter or cannula) and measurement of microvascular blood flow from deeper tissue regions.
Tissue placement via introducer (e.g. Angiocath®)
Removable/adjustable Luer
Dimensions:
Tip diameter: approx. 300 µm
Exposed tip fibre length 6 cm
Total probe length: 2.5 m
Reusability: Limited due to fragility
Nosaukums | |
---|---|
MSP100NX Standard probe for blood flow from tissue surfaces | |
MSP110NX Digit probe for blood flow from rounded surfaces | |
MSP300NX Miniature probe for blood flow from tissue surfaces (suturable) | |
MSP310NX Miniature probe for blood flow from tissue surfaces (non-suturable) | |
MNP100NXa Standard needle blood flow probe | |
MNP100NX-3_10 Standard needle blood flow probe for MCAO | |
MNP110NX Fine needle blood flow probe | |
MNP150NX Bent-tip needle blood flow probe | |
MSF100NX Single-fibre implantable blood flow probe | |
NX-BF_F Bare-fibre type blood flow probe |